Adams Rite Ps-Exit Power Supply

& Free Shipping

  • Initiated by switch closure to control each exit device.
  • Timer is user-configured and holds exit device in unlatched position for 2 – 60 seconds. At end of selected time, exit device will relatch.

Special Order

Want to be notified when this product is back in stock?

SKU: R8-PSEXIT Category:

Description

The PS-EXIT Power Supply is specifically designed to protect and optimize the performance of Adams Rite 8000/3000 Series exit devices with Motorized Latch Retraction (MLR) or Electric Latch Retraction (LR) options by delivering filtered and regulated power.

Function:

This power supply is designed to provide power and control for up to two MLR or LR exit devices. Each exit device is controlled by a timer that is initiated by a switch closure. The timer is user-configured and holds the exit device(s) in the unlatched position for 2 – 60 seconds. At the end of the selected time, the exit device(s) will re-latch. If the switch controlling the exit device is closed longer than the selected time, the exit device remains unlatched until the controlling switch is released.

  • An optional mode is available that allows both retraction timers to activate in response to a closure of either switch.
  • Exit devices under access system control remain latched during a complete power failure but always allow free mechanical egress

Certifications:

  • UL 294
  • CAN/CSA-C22.2 No. 223

Features:

Housing:ย Hinged, steel cabinet measures 10″ x10-3/8″ x 4-1/8″ [254 mm x 263.5 mm x104.8 mm]. Blue, baked enamel finish with knockouts for conduit connections. Sized to accommodate two sealed, lead acid batteries (7AH, not included).

Timer:ย Initiated by switch closure to control each exit device. Timer is user-configured and holds exit device in unlatched position for 2 – 60 seconds. At end of selected time, exit device will relatch.

Operating Modes: The PS-EXIT is designed to power up to two 8000/3000 MLR or LR exit devices in the following operating modes:

  • Single Input (Sequential Operation): either input retracts the corresponding exit device followed by retraction of second device. Control double-door exit with one input.
  • Dual Input (Independent Operation): Each exit device is controlled by its own input switch. Control two separate exits with two inputs.

Additional information

Weight 5 lbs
Brand