Edwards Signaling SD-2W SD Series SuperDuct 2-Wire Duct Smoke Detector, Photoelectric, 16-30VDC Operating Voltage, 50-750 Ohm Alarm Impedance
& Free Shipping
- PCB mounted photoelectric detector with onboard intelligence
- Environmental compensation with differential sensing for reliable, stable, and drift-free sensitivity
- Wide 0.79% to 2.46% obscuration/’. smoke sensitivity
Special Order
Description
Edwards-Signaling Duct Detector, 2 Wire, SD-2W
SuperDuct is a slim feature-rich alternative to bulky duct smoke detectors. Designed for easy installation and superb reliability, SuperDuct represents the perfect balance of practical design and advanced technology.
Super Duct 2 wire detector features a unique design that speeds installation and simplifies maintenance. Removable dust filters, conformally coated circuit boards, and optional water-resistant gaskets keep contaminants away from components, ensuring years of trouble-free service. ย When cleaning is required, the assemblies come apart easily and snap back together in seconds.
SuperDuct detectors use differential sensing to prevent small environmental changes from triggering false alarms. A rapid change in environmental conditions, such as smoke from a fire, causes the detector to automatically signal an alarm condition but dust and debris accumulated over time does not change alarm sensitivity.
The detector assembly cover provides easy access to the smoke sensor, its wiring connections, sample and exhaust tube fittings, and the smoke chamber itself. Air enters the detectorโs sensing chamber through a sampling tube (ordered separately) that extends into the duct and is directed back into the ventilation system through an exhaust tube (included). The difference in air pressure between the two tubes pulls the sampled air through the sensing chamber. When a sufficient amount of smoke is detected in the sensing chamber, the detector initiates an alarm.
Features
- PCB mounted photoelectric detector with onboard intelligence
- Environmental compensation with differential sensing for reliable, stable, and drift-free sensitivity
- Status LEDs remain visible through clear assembly cover
- Cover monitor switch for added security
- Standard sampling tube spacing for easy drop-in migration from other detectors
- Compatible with most Kiddeยฎ, FENWALยฎ, and Chemetronยฎ Conventional Control Panels
Technical Specifications
- Wide 0.79% to 2.46% obscuration/ft. smoke sensitivity
- -4ยฐF to 158ยฐF (-20ยฐC to 70ยฐC) operating range with 100 ft/min. to 4000 ft/min. air velocity rating assures reliability under harsh environmental conditions
- Less than 2″ deep for easy installation and applications where space is tight
- Magnet-activated test switch
- One Form C auxiliary alarm relay for controlling ancillary equipment (e.g., HVAC controls)
- Easy access to field connection terminals
Listing & Approvals
- FM Approved
- UL, ULC Listed
- CSFM Approved